Enviro Minder

The Enviro Minder is a remote monitor / data logger.It connects to your PC to continuously display and log the air temperature, relative humidity (RH) and Solar Irradiance (PAR). The PC allows you to set alarm conditions to audibly warn you if any variable goes out of range or send a phone message to a mobile phone or pager.

In addition, you can view the stored data graphically and quickly see what the conditions were like on any day of the growing season (or last season for that matter).

It can also monitor CO2 and provide a solar integrated trigger output for your irrigation system.

Specification – Enviro and Nutri Minders

These monitors can be used on-line to a PC or off-line for data logging

On-Line

Up to 128 devices may be connected in "daisy chain" fashion to the PC adapter. These can include any mix of the Minder series monitors, our AutoVent2 or 3 controllers or dosing/fertigation controller range NutriDose II.The monitors may be grouped into different systems. Usually a group will represent one greenhouse so that viewing is organised in a logical way.Data may be uploaded to the PC either every 1 or 5 minutes. This is set on the PC.Alarms may be set for each monitor and even for each measured variable. Data is logged to the hard disk of the computer for later graphical display.

Off-line

Whenever a PC is not connected the monitors continue in off-line mode. In this mode they record data every 5 minutes to an internal memory. They may then be carried to a PC and as soon as they switched on and connected to the computer, the data will be uploaded for logging to disk and display. The maximum data storage is limited to 10 days.

EC, pH, Temperature, run-off (EPT2000 monitor)

Display EC and pH to two decimal points resolution.Accuracy of EC and pH will depend on calibration If used in an electrically quiet area and properly calibrated at a temperature within 10 deg C of application temperature, accuracy will be better than +/- 0.2 errorTemperature accuracy better that 0.5 deg C without calibration, 0.2 deg C with calibration Easy to recalibrate in any standard solution. Calibrations are stored in permanent memory (ie they are still there is the power fails)Run-off quantity is measured by counting pulses from a flow meter. The run-off resolution will depend on the flow sensor used and can vary from 1 count per ml up to very large quantities per count. The unit will count up from zero to its maximum count of 1000 before restarting at zero and is reset at midnight. The total for each day is easily captured and summarised by the PC software. Very rugged "tipping bucket" flow sensors are useful with nutrient enriched water as they are less prone to jamming up due to crystallisation of the solution of moving parts

Air temperature, RH, CO2 and Solar (TRS2000)

Air temperature resolution: +/-0.1 deg CNutrient temperature resolution to 0.1 degC or degFAir temperature accuracy +/-0.5 deg C uncalibrated, 0.2 deg calibratedRelative Humidity accuracy +/- 5%CO2 accuracy depends on sensor supplied - a variety of sensors may be used with this instrument.Solar irradiance accuracy with low cost PAR sensor +/- 12%Solar irradiance accuracy with Apogee PAR sensor +/- 5%Solar integration to 999,000 mmol (999 mol)

Warranty

The warranty on the monitor, solar sensor and temperature sensor is limited to 2 years – return to factory. Before returning the unit for service you must call Autogrow Systems Ltd for a return authorisation (RMA) number.pH and RH sensors and fans carry only a 6 month warranty from their respective manufacturers.This warranty specifically excludes any parts that have been broken or damaged by water, chemical attach or excessive temperature. In particular, the monitor and PC interface must be stored and used in a dry, shaded and well ventilated situation. At no time must the case temperature be allowed to exceed 60 degC (140 deg F).

This warranty specifically excludes liability for consequential damages or for charges for labour or other expense in making repairs or adjustments, or loss of time or inconvenience.

Nutri Minder

The Nutrient Minder works the same as the Enviro minder but logs nutrient information instead. It will log and display EC (CF), pH, Nutrient Temperature and run-off quantity. This is useful for monitoring run-off from greenhouses to ensure that they comply with allowable run-off regulations. Both the Nutri-Minder and the Enviro-Minder can be configured to display European or USA date styles, EC or CF units, Deg C or Deg F

If your PC ever goes off-line the MINDERS will continue to log data for over a week. As soon as the PC is reconnected the locally stored data is automatically up-loaded.

T2000 - Remote Temperature Monitor

This low-cost remote monitor has a stainless steel sensor that can be placed in the nutrient, hydroponic gully, grow bed, or root zone. It does not have a local display nor the ability to data log locally and so must be connected online to the PC. When connected to the PC running Compugrow software it provides a continuous readout of temperature as well as a graphical record and high/low-temperature alarms. Besides its use in greenhouses, it is ideal for monitoring cool store temperatures, orchards, vineyards and even swimming pools.

Specification – Enviro and Nutri Minders

These monitors can be used on-line to a PC or off-line for data logging

On-Line

Up to 128 devices may be connected in a "daisy chain" fashion to the PC adapter. These can include any mix of the Minder series monitors, our AutoVent2 or 3 controllers, or dosing/fertigation controller range NutriDose II. The monitors may be grouped into different systems. Usually, a group will represent one greenhouse so that viewing is organized in a logical way. Data may be uploaded to the PC either every 1 or 5 minutes. This is set on the PC. Alarms may be set for each monitor and even for each measured variable. Data is logged to the hard disk of the computer for later graphical display.

Off-line

Whenever a PC is not connected the monitors continue in off-line mode. In this mode, they record data every 5 minutes to internal memory. They may then be carried to a PC and as soon as they are switched on and connected to the computer, the data will be uploaded for logging to disk and display. The maximum data storage is limited to 10 days.

EC, pH, Temperature, run-off (EPT2000 monitor)

Display EC and pH to two decimal points resolution. Accuracy of EC and pH will depend on calibration If used in an electrically quiet area and properly calibrated at a temperature within 10 deg C of application temperature, accuracy will be better than +/- 0.2 error temperature accuracy better than 0.5 deg C without calibration, 0.2 deg C with calibration Easy to recalibrate in any standard solution. Calibrations are stored in permanent memory (ie they are still there if the power fails)Run-off quantity is measured by counting pulses from a flow meter. The run-off resolution will depend on the flow sensor used and can vary from 1 count per ml up to very large quantities per count. The unit will count up from zero to its maximum count of 1000 before restarting at zero and is reset at midnight. The total for each day is easily captured and summarised by the PC software. Very rugged "tipping bucket" flow sensors are useful with nutrient-enriched water as they are less prone to jamming up due to the crystallization of the solution of moving parts

Air temperature, RH, CO2, and Solar (TRS2000)

Air temperature resolution: +/-0.1 deg CNutrient temperature resolution to 0.1 degC or degFAir temperature accuracy +/-0.5 deg C uncalibrated, 0.2 deg calibrated relative Humidity accuracy +/- 5%CO2 accuracy depends on sensor supplied - a variety of sensors may be used with this instrument.Solar irradiance accuracy with low-cost PAR sensor +/- 12%Solar irradiance accuracy with Apogee PAR sensor +/- 5%Solar integration to 999,000 mmol (999 mol)

Warranty

The warranty on the monitor, solar sensor, and temperature sensor is limited to 2 years – return to factory. Before returning the unit for service you must call Autogrow Systems Ltd for a return authorization (RMA) number. pH and RH sensors and fans carry only a 6-month warranty from their respective manufacturers. This warranty specifically excludes any parts that have been broken or damaged by water, chemical attaches, es or excessive temperature. In particular, the monitor and PC interface must be stored and used in a dry, shaded, and well-ventilated situation. At no time must the case temperature be allowed to exceed 60 deg C (140 deg F).

This warranty specifically excludes liability for consequential damages or for charges for labour or other expense in making repairs or adjustments, or loss of time or inconvenience.